SMHF4205D

Produktinformationen "Crane Interpoint SMHF4205D DC/DC-Wandler 35-55V, +/-5V, 1,68A Space Dualausgang"
Radiation tolerant space DC-DC converter
  • -Single event effects (SEE) LET performance to 86 MeV cm2/mg
  • -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si)
  • -50 - 300 rad(Si)/sec dose rate (Condition A)
  • -10 mrad(Si)/sec dose rate (Condition D) 
• Operating temperature -55°C to +125°C 
• Screened to MIL-PRF-38534 Class H and K
• Input voltage range 35 to 55 volts
• Transient protection 80 volts for 50 ms
• Fully isolated
• Fixed high frequency switching
• Inhibit function
• Synchronization input
• Indefinite short circuit protection
• Undervoltage lockout
Eingangsspannung VDC nom.: 42
Ausgangsspannung VDC: +/-5
Ausgangsstrom (A): 1,4 - 10
Leistungsklasse: Ultralow Power < 10W
Gehäuse: Metallgehäuse
Kühlmethode: Konvektion
Zielmarkt: Luft- & Raumfahrt
TBD
TBD

Verwandte Artikel

SMHF42-Serie

Crane Interpoint SMHF4205D DC/DC-Wandler 35-55V, +/-5V, 1,68A Space Dualausgang
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) • Operating temperature -55°C to +125°C • Screened to MIL-PRF-38534 Class H and K • Input voltage range 35 to 55 volts • Transient protection 80 volts for 50 ms • Fully isolated • Fixed high frequency switching • Inhibit function • Synchronization input • Indefinite short circuit protection • Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF4205S DC/DC-Wandler 35-55V, 5V, 2,4A Space
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) • Operating temperature -55°C to +125°C • Screened to MIL-PRF-38534 Class H and K • Input voltage range 35 to 55 volts • Transient protection 80 volts for 50 ms • Fully isolated • Fixed high frequency switching • Inhibit function • Synchronization input • Indefinite short circuit protection • Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF4212D DC/DC-Wandler 35-55V, +/-12V, 0,875A Space Dualausgang
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) • Operating temperature -55°C to +125°C • Screened to MIL-PRF-38534 Class H and K • Input voltage range 35 to 55 volts • Transient protection 80 volts for 50 ms • Fully isolated • Fixed high frequency switching • Inhibit function • Synchronization input • Indefinite short circuit protection • Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF4212S DC/DC-Wandler 35-55V, 12V, 1,25A Space
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) • Operating temperature -55°C to +125°C • Screened to MIL-PRF-38534 Class H and K • Input voltage range 35 to 55 volts • Transient protection 80 volts for 50 ms • Fully isolated • Fixed high frequency switching • Inhibit function • Synchronization input • Indefinite short circuit protection • Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF4215D DC/DC-Wandler 35-55V, +/-15V, 0,7A Space Dualausgang
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) • Operating temperature -55°C to +125°C • Screened to MIL-PRF-38534 Class H and K • Input voltage range 35 to 55 volts • Transient protection 80 volts for 50 ms • Fully isolated • Fixed high frequency switching • Inhibit function • Synchronization input • Indefinite short circuit protection • Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF4215S DC/DC-Wandler 35-55V, 15V, 1A Space
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) • Operating temperature -55°C to +125°C • Screened to MIL-PRF-38534 Class H and K • Input voltage range 35 to 55 volts • Transient protection 80 volts for 50 ms • Fully isolated • Fixed high frequency switching • Inhibit function • Synchronization input • Indefinite short circuit protection • Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF423R3S DC/DC-Wandler 35-55V, 3,3V, 2,4A Space
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) • Operating temperature -55°C to +125°C • Screened to MIL-PRF-38534 Class H and K • Input voltage range 35 to 55 volts • Transient protection 80 volts for 50 ms • Fully isolated • Fixed high frequency switching • Inhibit function • Synchronization input • Indefinite short circuit protection • Undervoltage lockout
zzgl. 19% MwSt.
Crane Interpoint SMHF425R2S DC/DC-Wandler 35-55V, 5,2V, 2,4A Space
Radiation tolerant space DC-DC converter -Single event effects (SEE) LET performance to 86 MeV cm2/mg -Total ionizing dose (TID) guaranteed per MIL-STD-883 method 1019, radiation hardness assurance (RHA) L = 50 krad(Si), R = 100 krad(Si) -50 - 300 rad(Si)/sec dose rate (Condition A) -10 mrad(Si)/sec dose rate (Condition D) • Operating temperature -55°C to +125°C • Screened to MIL-PRF-38534 Class H and K • Input voltage range 35 to 55 volts • Transient protection 80 volts for 50 ms • Fully isolated • Fixed high frequency switching • Inhibit function • Synchronization input • Indefinite short circuit protection • Undervoltage lockout
zzgl. 19% MwSt.
Newsletter Anmeldung Symbolbild

Newsletter

Abonnieren Sie jetzt kostenlos unseren E-Mail-Newsletter